David Valley's Real Estate/Home Inspection Blog

head_left_image

Purchasing a home with UNGROUNDED OUTLETS

There are a lot of homes on the market today that still have ungrounded outlets throughout the house. During my home inspections, I recommend that my clients upgrade some of these outlets, depending upon what they plan on utilizing these ungrounded outlets for.  Not all ungrounded outlets need to be upgraded, so let's go over (in detail) the options you have in upgrading ungrounded outlets.

Let's start off by distinguishing an ungrounded outlet from a grounded outlet.

 

The ungrounded outlets are easily distinguishable by their two slot configuration verses the newer grounded type of outlets that have the two slots with a hole (ground socket) centered under the slots. For this particular article, I will refer to these outlets as UNGROUNDED outlets and GROUNDED outlets.

Older wiring never contained a ground wire so any ungrounded outlets in your home were originally wired in this manner and are considered acceptable, but they do have their safety issues. Many ungrounded outlets have been installed in the older homes, but as the years went by the electrical standards have changed and are absolutely required in newer homes. While it is not usually required to upgrade ungrounded outlets in your home today, it is still a good idea because a properly wired home is a much safer home for you and your family.

 

THIS IS WHERE UNGROUNDED OUTLET PROBLEMS BEGIN...

The problems for owners of older homes start when two wire ungrounded outlets are removed and substituted with the grounded type outlets without the necessary rewiring that will add a ground wire to the newly installed grounded type outlet. People tend to replace 2 wire ungrounded outlets with ungrounded type outlets in order to establish a more convenient outlet for their three prong appliances. Most of today's appliance cords contain a three prong plug and it becomes a nuisance when homeowners (of ungrounded electrical systems) are attempting to locate three socket outlets for the grounded plugs. So they replace the two slotted ungrounded outlet with a grounded type outlet and it now becomes much more convenient for them to utilize these outlets in their home. But...these upgraded outlets are still not grounded without upgrading the entire branch wire that feeds the outlet.

Grounded type outlets are not suppose to be substituted for ungrounded outlets unless a new grounded wire is installed to this outlet. This will require a licensed Electrician to install the new wire from the load center to these grounded type outlets. An exception to this rule is allowed by the National Electrical Code, when the outlet is protected by a Ground Fault Circuit Interrupter (GFCI).

 

THIS BRINGS US TO... CHEAP FIXES OR UPGRADES.

There are cheap fixes available for those home owners who do not want to rewire their entire house. Perhaps one of the cheapest and simplest ways to address this issue is by utilizing a GFCI (also known as a Ground Fault Circuit interrupter). These can be installed in one of two locations. A GFCI outlet can take the place of a standard ungrounded outlet in any location and it now becomes a much safer outlet. Another option would be a GFCI breaker (at the load center) which takes the place of the regular circuit breaker. The N.E.C. (National Electrical Code) does allow GFCI's to replace two wire ungrounded outlets, but this might not be the greatest idea only because the round grounding socket on a GFCI outlet might give someone the false impression that the outlet has a grounding wire. So it's best to have these particular outlets clearly marked as "NO EQUIPMENT GROUND".

A GFCI replacement at an ungrounded outlet is a good choice for many expensive hard to re-wire cases. Instead of having an Electrician running newer wires to newer outlets, you will rely on the GFCI function to provide the personal protection at a much more convenient outlet. It is not the same as having a grounded outlet, but for most instances it is much safer. A GFCI outlet will trip (shut down) when there is a difference in the amount of current flowing through the neutral side of the electrical wiring. So, if a ground fault did occur, and some of the current starts to travel into the casing (toward you), a functional GFCI will automatically trip and stop all current flow, avoiding an electrical shock.

The one instance where a GFCI upgrade should not be used is where equipment utilizes a surge protector (like your computer's surge protector if you have one). Surge protectors use the ground wire to redirect any surge until it can trip. If a surge protector is plugged into an ungrounded outlet it will not operate as the manufacturer intended. When a large surge or spike does hit, the surge protector needs the ground wire to take the "hit" away from the protected equipment and send it safely to the ground wire which is connected to the load side. If the surge or spike is not sent to a ground wire by the surge protector it will destroy the delicate electronics that you were trying to protect. The surge protector manufacturer's do offer warranties, but...it's only valid if the surge protector is used in a properly grounded outlet.

 

HOW TO PROPERLY REPLACE AN UNGROUNDED OUTLET WITH A GFCI OUTLET

If you feel confident (in yourself) in replacing your ungrounded outlets, I will explain how you can do this project yourself. But, if electricity and it's components are one of the items that you'd rather not touch or if there are many outlets that need upgrading, I'd highly recommend you hire a licensed Electrician to perform this upgrade for you.

Before starting this project, please make sure the breaker (power) to this ungrounded outlet is shut down. Do not assume that the markings on your service panel are correct. Double-check that the power is shut down by plugging in a small appliance and turning it on. Once the power is off at this circuit, start by removing the screws from the outlet cover. Then remove the two screws at the outlet itself. Now pull the outlet out of the box and unscrew or release the two wires from the outlet. You can throw away this old outlet and the cover. The old two prong outlet cover will not adapt to the new GFCI outlet as it is shaped differently. Now take this opportunity to clean up the receptacle box with your shop vacuum before re-installing the GFCI outlet. Also, tape up any frayed or nicked wires with electrical tape (if the wires are badly deteriorated, you may have to trim them back or replace them with new wire). Now confirm that you have enough room in the box for the new GFCI by gently pushing the wires back in the box and test fitting the new GFCI. If the GFCI won't fit because there are too many wires in the box, you would have to have an Electrician install a new, larger electrical box.

Start the GFCI install by using needle nose pliers to bend the ends of the two existing wires into a u-shape, so they can fit snugly under each outlet screw. Now attach the black wire behind the head of the brass/gold screw and tighten it up, then attach the white wire behind the head of the silver screw and tighten this screw. (Remember, there is no ground wire at this location, so the green grounding screw on the GFCI outlet will be left blank). Now gently fold back the wires into the electrical box while pushing the GFCI outlet inside to sit flush against the box. You can now install the top and bottom screws to the outlet.

You should not have to force this outlet in. If you find yourself forcing the outlet to fit, then gently pull it out again and reorganize the wires and try it again. If you're still forcing wires inside the box, then you need to cut the wires shorter. Forcing an outlet may damage the wires and can pull them away from their outlet connections. Once you have the GFCI properly seated and screwed in, you can now screw the new GFCI outlet cover in place. Now the breaker to this circuit can be placed in the "On" position. You should now have a GFCI protected outlet that is SAFER but not grounded. REMEMBER: This outlet should always be labeled "NO EQUIPMENT GROUND" since the ground connection is left unconnected.

HINT: If you're goal is to protect every ungrounded outlet in the home with a GFCI outlet, it's not necessary to utilize a GFCI outlet in every single location. You can install ungrounded type outlets instead of GFCI outlets ONLY if they are wired through the LOAD side of a GFCI outlet. Still, no ground wire exists, so these outlets should be clearly labeled "GFCI PROTECTED, NO EQUIPMENT GROUND"

HINT: In many older homes the outlet mounting box was grounded from the load center but the outlet itself was not grounded. If this is the case it is possible to use a jumper between the mounting box and the grounding screw on the new grounded type outlet. But this  type of ground may not be adequate for a surge protector.

16 commentsDavid Valley • August 25 2007 07:55AM

Insulation Upgrade In Your Home

With as many homes as I've inspected, I'm surprised to see that so many areas are not insulated properly and are not to today's standards. Homeowners need more information in order to bring their home up to par. They can save themselves a lot of money on heating costs and roofing materials and at the same time prevent mold build-up due to improper installation of insulation. My applications apply to the Massachusetts area only and may change slightly due to the region you live in. Check with your municipal codes before  applying your insulation. (Example: Insulation vapor retarder is reversed in hotter climates and depths of insulation may differ, depending on where you live.)

 

Now I'd like to illustrate to home owners "HOW TO PROPERLY UPGRADE INSULATION IN YOUR HOME".

 

Very surprisingly, while most insulation is relatively very simple to install in a typical home, I often find that the attics are the most problematic areas. Both the insulation and ventilation are improperly installed on 75% of my home inspections throughout Massachusetts. This defect can lead to excessive heat loss and most importantly it will cause moisture to build-up and this continued moisture accumulation can effectively develop into major mold problems. I also find that many homes built prior to the early 1980's have an inadequate quantity of insulation installed above and below the living areas. Adequate insulation and Properly designed ventilation in the attic is critical for effective moisture-control and it will pro-long the life of asphalt shingles. For this reason, that is why I'm going to concentrate more on "HOW TO PROPERLY INSULATE AND VENTILATE YOUR ATTIC SPACE".

 

Before you even start to insulate, always read through the insulation manufacturer's instructions. Skipping any steps and taking shortcuts could mean significant reductions in R-value and a big waste of your money and effort. Allow yourself plenty of time and make sure you have enough materials to complete the entire job. If you're using rolled blankets of insulation, DO NOT open the package until you've hoisted it into the attic. The material will expand significantly (when opened), making it much harder to handle. Always wear goggles, a dust mask or respirator, gloves, long sleeves and long pants when working with insulation. Knee pads are also very helpful in the attic area, especially if there's no flooring in place and you're resting your knees on the floor joists. Be very careful moving around in your attic. Watch out for overhead rafters and those sharp nails that are protruding through the upper roof backings, and walk on the floor joists or sturdy floor boards only. If you were to walk between the floor joists, your foot will fall right through the drywall ceiling below. If you have adequate space in the attic, lay a plywood panel across floor joists to walk or kneel on. Do not allow plywood ends to float inside the floor joists. It's best to have the plywood properly cut to size, so it spans the spacing on the floor joists and sits on the floor joists at both ends of the plywood. Joist spacing will always vary from 16 to 24 or even 36 inches on center.

 

STEP 1

Very important...Make sure you have adequate ventilation installed before any new insulation is in put in place. NEVER cover over any of the existing attic vents, and leave at least one inch of airflow between the insulation and the roof backing, as shown here.

If ventilation is lacking, I recommend a roofing contractor install roof vents on the high side of the roof (preferably a ridge vent) and on the lower eave areas known as soffit vents or drip edge vents. The soffit vents should be equipped with Styrofoam baffles between the interior rafters (attached to the roof sheathing) leading into the soffit area in order to retain the air flow from the soffit area. They're very inexpensive and easy to install, just staple them in place onto the roof backing. Again, never cover the attic vents with the insulation. If your attic does not have roof vents installed, be sure to have a roofing contractor cut-in vents before installing any additional insulation. Your roofing contractor can advise you on what's best for your situation.

 

STEP 2

HOW MUCH INSULATION DO YOU NEED?

If you purchased (unfaced) insulation, you'll need to install a vapor retarder to prevent moisture damage. You can use pre-packaged vapor retarders or use 4- or 6-millimeter polyethylene sheeting. Vapor retarders should always go towards the warm side of the house. For attics, it needs to go under the insulation. If you purchased insulation with a Kraft-paper or foil facing, this facing should be placed down toward the inner ceiling (warm side of the home), but only the first layer should contain this facing. On any second or third layers, use unfaced blanket insulation or a blown-in insulating material. If you're using left-over faced insulation, you need to peel the paper off or simply slice long slits in the paper/foil facing (vapor retarder) to allow any moisture to pass right through the insulation.

When you're using batts or blankets to improve the existing R-value of the attic, use your utility knife to cut pieces to size. Place any second and third layers of blanket insulation at perpendicular to the lower layer. This technique will help lock in the thermal barrier and prevent any air gaps.

 

STEP 3

Look for electrical fixtures that protrude through your ceiling, especially recessed lighting. Since these fixtures can become hot when in use, you need to keep insulation a safe distance away from the top of these fixtures. Use a 1" x 4" or 1" x 6" piece of wood to create a retaining wall on all sides of the fixture. Keep the insulation at least three inches away from these fixtures. This application should also apply to the surrounding fireblock area around the chimney.

STEP 4

Fully insulate your attic access area. Keep in mind the most important rule is that you want to insulate any surface that divides inside (conditioned) living areas from outside (unconditioned) spaces. Therefore in an attic space that is not heated nor cooled, the outer most walls should be insulated because it is the barrier between the conditioned and the unconditioned space. In finished attics, the knee space (the outside wall cavities) should be insulated at the outside knee walls studs and inside the floor cavities. Behind a finished knee wall, insulation should not be installed in between the roof rafters. I continuously find this area improperly insulated on the majority of my inspections. A finished portion of the attic should look like this and an unfinished portion of the attic should look like this. Also...See the Diagram at the lower portion of this web page.

 

STEP 5

If your attic access is comprised of a pull down stairway or a scuttle hole opening, this area must be fully insulated to reduce infiltration and prevent heat loss through this passageway. Latch bolts should be installed to ensure an even tighter seal. There are manufactured insulated boxes on the market that'll fit perfectly over any pull down stairway. Or if your good with your carpentry skills, you can simply make your own box out of plywood and 2 X 4's. Design the box so it sits right along the outside edges of the attic opening and then fully insulate the outside of this box.

 

STEP 6

If you're hiring a professional to install blown-in insulation (loose fill) into the floor cavities, it's imperative to have them distribute it evenly across the entire attic area. Any gaps, holes or inconsistencies in depth will decrease the R-value. Make sure they are not blowing this insulation inside your already installed soffit vents or baffles, as this will block the air from entering your attic. Your objective for proper energy efficiency in New England's weather is to have 12-14 inches of blanket insulation or 9-10 inches of loose-fill insulation equaling an R-38 value.

 

RISKS OF ADDING MORE INSULATION

 

The diagram below is a perfectly insulated home. Let's start at the top and work our way down...

In UNFINISHED attic spaces, insulate between and over the floor joists to seal off all the living spaces below.

1A - Attic access door.

 

In FINISHED attics (with rooms) with or without a dormer, insulate the following...

 

2A - Between the studs of the knee walls.

2B - Between the studs and rafters of exterior walls and roof backing. Do not block vents or compress baffles.

2C - Ceiling cavities with cold spaces above.

2D - Extend the insulation right into the joist space (under living area) to reduce any air flows.

 

Insulate all exterior walls, including ...

 

3A - Walls between living spaces and unheated garages, shed roofs, or storage areas.

3B - Foundation walls above ground level.

3C - Foundation walls in heated basements, and full walls either on the interior or the exterior.

All floors above cold spaces, such as vented crawl spaces and unheated garages.

 

Also insulate ...

 

4A - Any portion of the floor cavity in a room that is cantilevered beyond the exterior wall below.

4B - Slab floors built directly on the ground.

4C - As an alternative to floor insulation, you can insulate the foundation walls of an unvented crawl space.

4D - Extend insulation into joist space (under the living area) to reduce any air flows.

5 - All Band or Rim Joists throughout the exterior wall.

6 - To finalize the efficiency of your home, replace any single pane windows with Thermal Pane windows and caulk and seal around every window and door trim piece.

6 commentsDavid Valley • August 05 2007 06:39AM